China Good quality Quality Assured 1.5kw Three Phase Induction AC 100% Cooper Wire Wholesale Motor with Best Price vacuum pump for ac

Product Description

Product Description

 Y series motors are totally enclosed fan cooled(TEFC).squirrel cage three-phase induction motors,developed with new technique They are renewal and upgrading products of Y-series The mounting dimension is fully comformed with IEC standard. The motors have the merits of beautiful modeling ,compact structure ,low noise,high efficiency,large staring torque,easy serving,etc The motors are adopted with F class insulation and designed with assessing method for insulation practice,it enhances greatly motor’s safety and reliability.These motors have reached an international advandced level  Y series motors can be widely used in various machines and equipments,such as drilling machines ,blower ,pumps,compressors,transporters, agricultural and food processing machines.

Ambient Temperature

-15ºC≤0≤40ºC

Altitude

Not exceeding 1000 CHINAMFG

Rated Voltage

380V±5%

Protection Type

IP44/IP54

Connection

Y Start-Connection for 3 Kw and below

Y Date-Connection for 3 Kw or more

Cooling Type 

IC0141

Insulation Class

Class B/Class F

Rated Frequency

50Hz/60Hz

Duty/Rating

Continuous(S1) Or customized 

The terminal box IP55

If you need more information, please contact us.

 

Product Parameters

Type Power (kw) Current (A) Speed (r/min) Eff.% P.F N.m Tst
Tn
Ist
Tn
Tmax
Tn
dB(A)
synchronous speed 3000 r/min
YE3-63M1-2 0.18 0.53 2720 63.9 0.8 0.63 2.2 5.5 2.2 61
YE3-63M2-2 0.25 0.70  2720 67.1 0.81 0.88 2.2 5.5 2.2 61
YE3-71M1-2 0.37 1.0  2740 69.0  0.81 1.29 2.2 6.1 2.2 62
YE3-71M2-2 0.55 1.4 2870 72.3 0.82 1.92 2.2 6.1 2.2 62
YE3-80M1-2 0.75 1.7 2875 80.7 0.82 2.50  2.2 7.0  2.3 62
YE3-80M2-2 1.1 2.4 2880 82.7 0.83 3.65 2.2 7.3 2.3 62
YE3-90S-2 1.5 3.2 2880 84.2 0.84 4.97 2.2 7.6 2.3 67
YE3-90L-2 2.2 4.6 2880 85.9 0.85 7.30  2.2 7.6 2.3 67
YE3-100L-2 3 6.0  2915 87.1 0.87 9.95 2.2 7.8 2.3 74
YE3-112M-2 4 7.8 2935 88.1 0.88 13.1 2.2 8.3 2.3 77
YE3-132S1-2 5.5 10.6 2930 89.2 0.88 17.9 2.0  8.3 2.3 79
YE3-132S2-2 7.5 14.4 2950 90.1 0.88 24.4 2.0  7.9 2.3 79
YE3-160M1-2 11 20.6 2945 91.2 0.89 35.6 2.0  8.1 2.3 81
YE3-160M2-2 15 27.9 2945 91.9 0.89 48.6 2.0  8.1 2.3 81
YE3-160L-2 18.5 34.2 2950 92.4 0.89 60.0  2.0  8.2 2.3 81
YE3-180M-2 22 40.5 2965 92.7 0.89 71.2  2.0  8.2 2.3 84
YE3-200L1-2 30 54.9 2965 93.3 0.89 96.6 2.0  7.6 2.3 84
YE3-200L2-2 37 67.4 2965 93.7 0.89 119 2.0  7.6 2.3 86
YE3-225M-2 45 80.8 2965 94.0  0.90  145 2.0  7.7 2.3 89
YE3-250M-2 55 98.5 2975 94.3 0.90  177 2.0  7.7 2.3 91
YE3-280S-2 75 134 2975 94.7 0.90  241 1.8 7.1 2.3 91
YE3-280M-2 90 160 2975 95.0  0.90  289 1.8 7.1 2.3 92
YE3-315S-2 110 195 2985 95.2 0.90  352 1.8 7.1 2.3 92
YE3-315M-2 132 234 2985 95.4 0.90  422 1.8 7.1 2.3 92
YE3-315L1-2 160 279 2985 95.6 0.91 512 1.8 7.2 2.3 92
YE3-315L-2 185 323 2985 95.7 0.91 592 1.8 7.2 2.3 92
YE3-315L2-2 200 349 2985 95.8 0.91 640 1.8 7.2 2.2 100
YE3-315L3-2 220 383 2985 95.8 0.91 704 1.8 7.2 2.2 100
YE3-355M1-2 220 383 2985 95.8 0.91 704 1.8 7.2 2.2 100
YE3-355M-2 250 436 2985 95.8 0.91 800 1.6 7.2 2.2 100
YE3-355L1-2 280 488 2985 95.8 0.91 896 1.6 7.2 2.2 100
YE3-355L-2 315 549 2985 95.8 0.91 1008 1.6 7.2 2.2 100
YE3-355L2-2 355 619 2985 95.8 0.91 1136 1.6 7.2 2.2 100
YE3-355L3-2 375 654 2985 95.8 0.91 1200 1.6 7.2 2.2 100

Type Power (kw) Current (A) Speed (r/min) Eff.% P.F N.m Tst
Tn
Ist
Tn
Tmax
Tn
dB(A)
synchronous speed 1500 r/min  
YE3-63M1-4 0.12 0.45 1310 55.8 0.72 0.87 2.1 4.4 2.2 52
YE3-63M2-4 0.18 0.64 1310 58.6 0.73 1.31 2.1 4.4 2.2 52
YE3-71M1-4 0.25 0.81 1330 63.6 0.74 1.8 2.1 5.2 2.2 55
YE3-71M2-4 0.37 1.1 1330 65.3 0.75 2.66 2.1 5.2 2.2 55
YE3-80M1-4 0.55 1.4 1430 80.6 0.75 3.67 2.3 6.5 2.3 56
YE3-80M2-4 0.75 1.8 1430 82.5 0.75 5.01 2.3 6.6 2.3 56
YE3-90S-4 1.1 2.6 1430 84.1 0.76 7.35 2.3 6.8 2.3 59
YE3-90L-4 1.5 3.5 1430 85.3 0.77 10 2.3 7.0  2.3 59
YE3-100L1-4 2.2 4.8 1440 86.7 0.81 14.6 2.3 7.6 2.3 64
YE3-100L2-4 3 6.3 1440 87.7 0.82 19.9 2.3 7.6 2.3 64
YE3-112M-4 4 8.4 1455 88.6 0.82 26.3 2.2 7.8 2.3 65
YE3-132S-4 5.5 11.2 1465 89.6 0.83 35.9 2.0  7.9 2.3 71
YE3-132M-4 7.5 15.0  1465 90.4 0.84 48.9 2.0  7.5 2.3 71
YE3-160M-4 11 21.5 1470 91.4 0.85 71.5 2.0  7.7 2.3 73
YE3-160L-4 15 28.8 1470 92.1 0.86 97.4 2.0  7.8 2.3 73
YE3-180M-4 18.5 35.3 1470 92.6 0.86 120 2.0  7.8 2.3 76
YE3-180L-4 22 41.8 1470 93.0  0.86 143 2.0  7.8 2.3 76
YE3-200L-4 30 56.6 1475 93.6 0.86 194 2.0  7.3 2.3 76
YE3-225S-4 37 69.6 1480 93.9 0.86 239 2.0  7.4 2.3 78
YE3-225M-4 45 84.4 1480 94.2 0.86 290 2.0  7.4 2.3 78
YE3-250M-4 55 103 1485 94.6 0.86 354 2.0  7.4 2.3 79
YE3-280S-4 75 136 1490 95.0  0.88 481 2.0  6.7 2.3 80
YE3-280M-4 90 163 1490 95.2 0.88 577 2.0  6.9 2.3 80
YE3-315S-4 110 197 1490 95.4 0.89 705 2.0  7.0  2.2 88
YE3-315M-4 132 236 1490 95.6 0.89 846 2.0  7.0  2.2 88
YE3-315L1-4 160 285 1490 95.8 0.89 1026 2.0  7.1 2.2 88
YE3-315L-4 185 329 1490 95.9 0.89 1186 2.0  7.1 2.2 88
YE3-315L2-4 200 352 1490 96.0  0.90  1282 2.0  7.1 2.2 88
YE3-315L3-4 220 387 1490 96.0  0.90  1410 2.0  7.1 2.2 88
YE3-355M1-4 220 387 1490 96.0  0.90  1410 2.0  7.1 2.2 95
YE3-355M-4 250 440 1495 96.0  0.90  1597 2.0  7.1 2.2 95
YE3-355L1-4 280 492 1495 96.0  0.90  1789 2.0  7.1 2.2 95
YE3-355L-4 315 554 1495 96.0  0.90  2012 2.0  7.1 2.2 95
YE3-355L2-4 355 638 1495 96.0  0.88 2268 1.7 7.0  2.2 95
YE3-355L3-4 375 674 1495 96.0  0.88 2395 1.7 7.0  2.2 95

Type Power (kw) Current (A) Speed (r/min) Eff.% P.F N.m Tst
Tn
Ist
Tn
Tmax
Tn
dB(A)
synchronous speed 1000 r/min
YE3-71M1-6 0.18 0.76 850 54.6 0.66 2.02 1.9 4.0  2.0  52
YE3-71M2-6 0.25 0.97 850 57.4 0.66 2.81 1.9 4.0  2.0  52
YE3-80M1-6 0.37 1.2 910 68 0.70  3.88 1.9 5.5 2.0  54
YE3-80M2-6 0.55 1.6 925 72 0.71 5.68 1.9 5.8 2.1 54
YE3-90S-6 0.75 2 945 78.9 0.71 7.58 2.0  6.0  2.1 57
YE3-90L-6 1.1 2.8 950 81 0.73 11.1 2.0  6.0  2.1 57
YE3-100L-6 1.5 3.8 950 82.5 0.73 15.1 2.0  6.5 2.1 61
YE3-112M-6 2.2 5.4 965 84.3 0.74 21.8 2.0  6.6 2.1 65
YE3-132S-6 3 7.2 975 85.6 0.74 29.4 1.9 6.8 2.1 69
YE3-132M1-6 4 9.5 975 86.8 0.74 39.2 1.9 6.8 2.1 69
YE3-132M2-6 5.5 12.7 975 88.0  0.75 53.9 1.9 7.0  2.1 69
YE3-160M-6 7.5 16.2 980 89.1 0.79 73.1 1.9 7.0  2.1 70
YE3-160L-6 11 23.1 980 90.3 0.80  107 1.9 7.2 2.1 70
YE3-180L-6 15 30.9 980 91.2  0.81 146 1.9 7.3 2.1 73
YE3-200L1-6 18.5 37.8 985 91.7 0.81 179 1.9 7.3 2.1 73
YE3-200L2-6 22 44.8 985 92.2 0.81 213 1.9 7.4 2.1 73
YE3-225M-6 30 59.1 985 92.9 0.83 291 1.9 6.9 2.1 74
YE3-250M-6 37 71.7 985 93.3 0.84 359 1.9 7.1 2.1 76
YE3-280S-6 45 85.8 990 93.7 0.85 434 1.9 7.3 2.0  78
YE3-280M-6 55 103 990 94.1 0.86 531 1.9 7.3 2.0  78
YE3-315S-6 75 143 990 94.6 0.84 723 1.9 6.6 2.0  83
YE3-315M-6 90 170 990 94.9 0.85 868 1.9 6.7 2.0  83
YE3-315L1-6 110 207 990 95.1 0.85 1061 1.9 6.7 2.0  83
YE3-315L2-6 132 244 990 95.4 0.86 1273 1.9 6.8 2.0  83
YE3-315L3-6 160 296 990 95.6 0.86 1543 1.9 6.8 2.0  83
YE3-355M1-6 160 296 995 95.6 0.86 1536 1.9 6.8 2.0  85
YE3-355M-6 185 342 995 95.7 0.86 1776 1.9 6.8 2.0  85
YE3-355M2-6 200 365 995 95.8 0.87 1920 1.9 6.8 2.0  85
YE3-355L1-6 220 401 995 95.8 0.87 2112 1.9 6.8 2.0  85
YE3-355L-6 250 456 995 95.8 0.87 2399 1.9 6.8 2.0  85
YE3-355L2-6 280 510 995 95.8 0.87 2687 1.9 6.8 2.0  85
YE3-355L3-6 315 581 995 95.8 0.86 3571 1.9 6.8 2.0  85
                     
                     
                     
                     
Type Power (kw) Current (A) Speed (r/min) Eff.% P.F N.m Tst
Tn
Ist
Tn
Tmax
Tn
dB(A)
synchronous speed 750 r/min
YE3-80M1-8 0.18 0.80  700 56.0  0.61 2.46 1.8 3.3 1.9 52
YE3-80M2-8 0.25 1.1 700 59.0  0.61 3.41 1.8 3.3 1.9 52
YE3-90S-8 0.37 1.4 695 66.0  0.61 5.08 1.8 4.0  1.9 56
YE3-90L-8 0.55 2.0  695 70.0  0.61 7.56 1.8 4.0  2.0  56
YE3-100L1-8 0.75 2.3 705 73.5 0.67 10.2 1.8 4.0  2.0  59
YE3-100L2-8 1.1 3.2 705 76.5 0.69 14.9 1.8 5.0  2.0  59
YE3-112M-8 1.5 4.2 715 77.5 0.70  20.0  1.8 5.0  2.0  61
YE3-132S-8 2.2 5.9 730 80.0  0.71 28.8 1.8 6.0  2.2 64
YE3-132M-8 3 7.6 730 82.5 0.73 39.2 1.8 6.0  2.2 64
YE3-160M1-8 4 9.8 725 85.0  0.73 52.7 1.9 6.0  2.2 68
YE3-160M2-8 5.5 13.1 725 86.0  0.74 72.4 1.9 6.0  2.2 68
YE3-160L-8 7.5 17.4 730 87.5 0.75 98.1 1.9 6.0  2.2 68
YE3-180L-8 11 25.0  725 89.0  0.75 145 1.9 6.5 2.2 70
YE3-200L-8 15 33.2 730 90.4 0.76 196 2.0  6.6 2.2 73
YE3-225S-8 18.5 40.6 735 91.2 0.76 240 2.0  6.6 2.2 73
YE3-225M-8 22 46.8 735 91.5 0.78 286 2.0  6.6 2.2 73
YE3-250M-8 30 62.6 735 92.2 0.79 390 1.9 6.5 2.0  75
YE3-280S-8 37 76.5 740 93.0  0.79 478 1.8 6.6 2.0  76
YE3-280M-8 45 92.6 740 93.5 0.79 581 1.8 6.6 2.0  76
YE3-315S-8 55 110 740 93.8 0.81 710 1.8 6.6 2.0  82
YE3-315M-8 75 150 740 94.0  0.81 968 1.8 6.2 2.0  82
YE3-315L1-8 90 176 740 94.5 0.82 1161 1.8 6.4 2.0  82
YE3-315L2-8 110 215 740 94.8 0.82 1420 1.8 6.4 2.0  82
YE3-355M1-8 132 257 745 95.0  0.82 1692 1.8 6.4 2.0  90
YE3-355M2-8 160 312 745 95.0  0.82 2051 1.8 6.4 2.0  90
YE3-355L1-8 185 360 745 95.2 0.82 2371 1.8 6.4 2.0  90
YE3-355L-8 200 385 745 95.2 0.83 2564 1.8 6.4 2.0  90
YE3-355L2-8 220 423 745 95.2 0.83 2820 1.8 6.4 2.0  90
YE3-355L3-8 250 481 745 95.2 0.83 3205 1.8 6.5 2.0  90
synchronous speed 600 r/min
YE3-315S-10 45 99 590 92.0  0.75 728 1.5 6.2 2.0  90
YE3-315M-10 55 120 590 92.5 0.75 890 1.5 6.2 2.0  90
YE3-315L1-10 75 161 590 93.0  0.76 1214 1.5 5.8 2.0  90
YE3-315L2-10 90 190 590 93.4 0.77 1457 1.5 5.9 2.0  90
YE3-355M1-10 110 228 595 93.8 0.78 1766 1.3 6.0  2.0  90
YE3-355M2-10 132 273 595 94.2 0.78 2119 1.3 6.0  2.0  90
YE3-355L1-10 160 331 595 94.2 0.78 2568 1.3 6.0  2.0  90
YE3-355L-10 185 383 595 94.2 0.78 2969 1.3 6.0  2.0  90
YE3-355L2-10 200 414 595 94.2 0.78 3210 1.3 6.0  2.0  90

Detailed Photos

FAQ

Q: Where is Your factory?
A: HangZhou city, ZHangZhoug Province.
 
Q: Do you accept OEM/ODM service?
A: Yes, avaliable.
 
Q: Are you trading company or manufacturer?
A: We are a manufacturer.
 
Q: What about the shipment?
A: By sea, By air and By express delivery.
 
Q: What is the delivery time?
A: It depends on the order quantity, usually 35days after confirmation.
 
Q: Can I buy different products in 1 container?
A: Yes, but no more than 5 models.
 
Q: What is the warranty time?
A: One year.

Q: Can you offer the sample?
A: Of course we can.

/* January 22, 2571 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

Application: Industrial, Universal, Household Appliances
Operating Speed: Constant Speed
Number of Stator: Three-Phase
Species: Y, Y2 Series Three-Phase
Rotor Structure: Squirrel-Cage
Casing Protection: Closed Type
Samples:
US$ 85.29/Piece
1 Piece(Min.Order)

|

Customization:
Available

|

induction motor

What role do AC motors play in HVAC (heating, ventilation, and air conditioning) systems?

In HVAC (heating, ventilation, and air conditioning) systems, AC motors play a crucial role in various components and functions. These motors are responsible for powering fans, compressors, pumps, and other essential equipment within the HVAC system. Let’s explore the specific roles of AC motors in HVAC systems:

  • Air Handling Units (AHUs) and Ventilation Systems: AC motors drive the fans in AHUs and ventilation systems. These fans draw in fresh air, circulate air within the building, and exhaust stale air. The motors provide the necessary power to move air through the ductwork and distribute it evenly throughout the space. They play a key role in maintaining proper indoor air quality, controlling humidity, and ensuring adequate ventilation.
  • Chillers and Cooling Towers: HVAC systems that use chillers for cooling rely on AC motors to drive the compressor. The motor powers the compressor, which circulates refrigerant through the system, absorbing heat from the indoor environment and releasing it outside. AC motors are also used in cooling towers, which dissipate heat from the chiller system by evaporating water. The motors drive the fans that draw air through the cooling tower and enhance heat transfer.
  • Heat Pumps: AC motors are integral components of heat pump systems, which provide both heating and cooling. The motor drives the compressor in the heat pump, enabling the transfer of heat between the indoor and outdoor environments. During cooling mode, the motor circulates refrigerant to extract heat from indoors and release it outside. In heating mode, the motor reverses the refrigerant flow to extract heat from the outdoor air or ground and transfer it indoors.
  • Furnaces and Boilers: In heating systems, AC motors power the blowers or fans in furnaces and boilers. The motor drives the blower to distribute heated air or steam throughout the building. This helps maintain a comfortable indoor temperature and ensures efficient heat distribution in the space.
  • Pumps and Circulation Systems: HVAC systems often incorporate pumps for water circulation, such as in hydronic heating or chilled water systems. AC motors drive these pumps, providing the necessary pressure to circulate water or other heat transfer fluids through the system. The motors ensure efficient flow rates and contribute to the effective transfer of thermal energy.
  • Dampers and Actuators: AC motors are used in HVAC systems to control airflow and regulate the position of dampers and actuators. These motors enable the adjustment of airflow rates, temperature control, and zone-specific climate control. By modulating the motor speed or position, HVAC systems can achieve precise control of air distribution and temperature in different areas of a building.

AC motors in HVAC systems are designed to meet specific performance requirements, such as variable speed control, energy efficiency, and reliable operation under varying loads. Maintenance and regular inspection of these motors are essential to ensure optimal performance, energy efficiency, and longevity of the HVAC system.

In conclusion, AC motors play vital roles in HVAC systems by powering fans, compressors, pumps, and actuators. They enable proper air circulation, temperature control, and efficient transfer of heat, contributing to the overall comfort, air quality, and energy efficiency of buildings.

induction motor

What are the common signs of AC motor failure, and how can they be addressed?

AC motor failure can lead to disruptions in various industrial and commercial applications. Recognizing the common signs of motor failure is crucial for timely intervention and preventing further damage. Here are some typical signs of AC motor failure and potential ways to address them:

  • Excessive Heat: Excessive heat is a common indicator of motor failure. If a motor feels excessively hot to the touch or emits a burning smell, it could signify issues such as overloaded windings, poor ventilation, or bearing problems. To address this, first, ensure that the motor is properly sized for the application. Check for obstructions around the motor that may be impeding airflow and causing overheating. Clean or replace dirty or clogged ventilation systems. If the issue persists, consult a qualified technician to inspect the motor windings and bearings and make any necessary repairs or replacements.
  • Abnormal Noise or Vibration: Unusual noises or vibrations coming from an AC motor can indicate various problems. Excessive noise may be caused by loose or damaged components, misaligned shafts, or worn bearings. Excessive vibration can result from imbalanced rotors, misalignment, or worn-out motor parts. Addressing these issues involves inspecting and adjusting motor components, ensuring proper alignment, and replacing damaged or worn-out parts. Regular maintenance, including lubrication of bearings, can help prevent excessive noise and vibration and extend the motor’s lifespan.
  • Intermittent Operation: Intermittent motor operation, where the motor starts and stops unexpectedly or fails to start consistently, can be a sign of motor failure. This can be caused by issues such as faulty wiring connections, damaged or worn motor brushes, or problems with the motor’s control circuitry. Check for loose or damaged wiring connections and make any necessary repairs. Inspect and replace worn or damaged motor brushes. If the motor still exhibits intermittent operation, it may require professional troubleshooting and repair by a qualified technician.
  • Overheating or Tripping of Circuit Breakers: If an AC motor consistently causes circuit breakers to trip or if it repeatedly overheats, it indicates a problem that needs attention. Possible causes include high starting currents, excessive loads, or insulation breakdown. Verify that the motor is not overloaded and that the load is within the motor’s rated capacity. Check the motor’s insulation resistance to ensure it is within acceptable limits. If these measures do not resolve the issue, consult a professional to assess the motor and its electrical connections for any faults or insulation breakdown that may require repair or replacement.
  • Decreased Performance or Efficiency: A decline in motor performance or efficiency can be an indication of impending failure. This may manifest as reduced speed, decreased torque, increased energy consumption, or inadequate power output. Factors contributing to decreased performance can include worn bearings, damaged windings, or deteriorated insulation. Regular maintenance, including lubrication and cleaning, can help prevent these issues. If performance continues to decline, consult a qualified technician to inspect the motor and perform any necessary repairs or replacements.
  • Inoperative Motor: If an AC motor fails to operate entirely, there may be an issue with the power supply, control circuitry, or internal motor components. Check the power supply and connections for any faults or interruptions. Inspect control circuitry, such as motor starters or contactors, for any damage or malfunction. If no external faults are found, it may be necessary to dismantle the motor and inspect internal components, such as windings or brushes, for any faults or failures that require repair or replacement.

It’s important to note that motor failure causes can vary depending on factors such as motor type, operating conditions, and maintenance practices. Regular motor maintenance, including inspections, lubrication, and cleaning, is essential for early detection of potential failure signs and for addressing issues promptly. When in doubt, it is advisable to consult a qualified electrician, motor technician, or manufacturer’s guidelines for appropriate troubleshooting and repair procedures specific to the motor model and application.

induction motor

Can you explain the basic working principle of an AC motor?

An AC motor operates based on the principles of electromagnetic induction. It converts electrical energy into mechanical energy through the interaction of magnetic fields. The basic working principle of an AC motor involves the following steps:

  1. The AC motor consists of two main components: the stator and the rotor. The stator is the stationary part of the motor and contains the stator windings. The rotor is the rotating part of the motor and is connected to a shaft.
  2. When an alternating current (AC) is supplied to the stator windings, it creates a changing magnetic field.
  3. The changing magnetic field induces a voltage in the rotor windings, which are either short-circuited conductive bars or coils.
  4. The induced voltage in the rotor windings creates a magnetic field in the rotor.
  5. The magnetic field of the rotor interacts with the rotating magnetic field of the stator, resulting in a torque force.
  6. The torque force causes the rotor to rotate, transferring mechanical energy to the connected shaft.
  7. The rotation of the rotor continues as long as the AC power supply is provided to the stator windings.

This basic working principle is applicable to various types of AC motors, including induction motors and synchronous motors. However, the specific construction and design of the motor may vary depending on the type and intended application.

China Good quality Quality Assured 1.5kw Three Phase Induction AC 100% Cooper Wire Wholesale Motor with Best Price   vacuum pump for ac	China Good quality Quality Assured 1.5kw Three Phase Induction AC 100% Cooper Wire Wholesale Motor with Best Price   vacuum pump for ac
editor by CX 2024-03-06

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *